Transient behaviour of ITER poloidal field coils

Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made us...

Full description

Saved in:
Bibliographic Details
Main Author: Winkler, Alexander
Format: Online
Language:English
Published: KIT Scientific Publishing 2021
Subjects:
Online Access:35678
Tags: Add Tag
No Tags, Be the first to tag this record!
_version_ 1869528303503671296
author Winkler, Alexander
author_browse Winkler, Alexander
author_facet Winkler, Alexander
author_sort Winkler, Alexander
collection Directory of Open Access Books
description Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made using the PF 3 and PF 6 coils as examples. The calculated maximum voltages will be used for definition of amplitudes and voltage waveforms for the tests of the high-voltage insulation of the coils.
format Online
id doab-20.500.12854ir-61213
institution Directory of Open Access Books
language eng
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher KIT Scientific Publishing
publisherStr KIT Scientific Publishing
record_format ojs
spelling doab-20.500.12854ir-612132024-04-09T23:15:41Z Transient behaviour of ITER poloidal field coils Winkler, Alexander T1-995 high-voltage insulation Superconducting coils transient voltages FEM and network calculations thema EDItEUR::T Technology, Engineering, Agriculture, Industrial processes::TB Technology: general issues Transient voltages occur on the terminals of superconducting coils and may lead to internal over-voltages. The main objective of this work was to calculate the transient electrical behaviour and internal voltage distribution within the ITER poloidal field (PF) coils at four scenarios and was made using the PF 3 and PF 6 coils as examples. The calculated maximum voltages will be used for definition of amplitudes and voltage waveforms for the tests of the high-voltage insulation of the coils. 2021-02-12T06:24:12Z 2021-02-12T06:24:12Z 2019-07-30 20:02:02 2011 book 35678 18691765 9783866445956 https://directory.doabooks.org/handle/20.500.12854/61213 eng Karlsruher Schriftenreihe zur Supraleitung / Hrsg. Prof. Dr.-Ing. M. Noe, Prof. Dr. rer. nat. M. Siegel image/jpeg Attribution-NonCommercial-NoDerivatives 4.0 International https://www.ksp.kit.edu/9783866445956 KIT Scientific Publishing 10.5445/KSP/1000020684 10.5445/KSP/1000020684 68fffc18-8f7b-44fa-ac7e-0b7d7d979bd2 9783866445956 165 p. open access
spellingShingle T1-995
high-voltage insulation
Superconducting coils
transient voltages
FEM and network calculations
thema EDItEUR::T Technology, Engineering, Agriculture, Industrial processes::TB Technology: general issues
Winkler, Alexander
Transient behaviour of ITER poloidal field coils
title Transient behaviour of ITER poloidal field coils
title_full Transient behaviour of ITER poloidal field coils
title_fullStr Transient behaviour of ITER poloidal field coils
title_full_unstemmed Transient behaviour of ITER poloidal field coils
title_short Transient behaviour of ITER poloidal field coils
title_sort transient behaviour of iter poloidal field coils
topic T1-995
high-voltage insulation
Superconducting coils
transient voltages
FEM and network calculations
thema EDItEUR::T Technology, Engineering, Agriculture, Industrial processes::TB Technology: general issues
topic_facet T1-995
high-voltage insulation
Superconducting coils
transient voltages
FEM and network calculations
thema EDItEUR::T Technology, Engineering, Agriculture, Industrial processes::TB Technology: general issues
url 35678
work_keys_str_mv AT winkleralexander transientbehaviourofiterpoloidalfieldcoils