Chapter Measuring Energy

Data centres are part of today's critical information and communication infrastructure, and the majority of business transactions as well as much of our digital life now depend on them. At the same time, data centres are large primary energy consumers, with energy consumed by IT and server room air...

সম্পূর্ণ বিবরণ

সংরক্ষণ করুন:
গ্রন্থ-পঞ্জীর বিবরন
প্রধান লেখক: Kerrison, Steve, Buschhoff, Markus, Nunez-Yanez, Jose, Eder, Kerstin
বিন্যাস: Online
ভাষা:ইংরেজি
প্রকাশিত: InTechOpen 2021
বিষয়গুলি:
অনলাইন ব্যবহার করুন:ONIX_20210602_10.5772/65989_305
ট্যাগগুলো: ট্যাগ যুক্ত করুন
কোনো ট্যাগ নেই, প্রথমজন হিসাবে ট্যাগ করুন!
_version_ 1869528488240742400
author Kerrison, Steve
Buschhoff, Markus
Nunez-Yanez, Jose
Eder, Kerstin
author_browse Buschhoff, Markus
Eder, Kerstin
Kerrison, Steve
Nunez-Yanez, Jose
author_facet Kerrison, Steve
Buschhoff, Markus
Nunez-Yanez, Jose
Eder, Kerstin
author_sort Kerrison, Steve
collection Directory of Open Access Books
description Data centres are part of today's critical information and communication infrastructure, and the majority of business transactions as well as much of our digital life now depend on them. At the same time, data centres are large primary energy consumers, with energy consumed by IT and server room air conditioning equipment and also by general building facilities. In many data centres, IT equipment energy and cooling energy requirements are not always coordinated, so energy consumption is not optimised. Most data centres lack an integrated energy management system that jointly optimises and controls all its energy consuming equipments in order to reduce energy consumption and increase the usage of local renewable energy sources. In this chapter, the authors discuss the challenges of coordinated energy management in data centres and present a novel scalable, integrated energy management system architecture for data centre wide optimisation. A prototype of the system has been implemented, including joint workload and thermal management algorithms. The control algorithms are evaluated in an accurate simulation‐based model of a real data centre. Results show significant energy savings potential, in some cases up to 40%, by integrating workload and thermal management.
format Online
id doab-20.500.12854ir-70280
institution Directory of Open Access Books
language eng
publishDate 2021
publishDateRange 2021
publishDateSort 2021
publisher InTechOpen
publisherStr InTechOpen
record_format ojs
spelling doab-20.500.12854ir-702802024-04-09T11:41:25Z Chapter Measuring Energy Kerrison, Steve Buschhoff, Markus Nunez-Yanez, Jose Eder, Kerstin energy efficient data centres, workload management, thermal management, integrated data centre energy management platform thema EDItEUR::R Earth Sciences, Geography, Environment, Planning::RN The environment::RNU Sustainability Data centres are part of today's critical information and communication infrastructure, and the majority of business transactions as well as much of our digital life now depend on them. At the same time, data centres are large primary energy consumers, with energy consumed by IT and server room air conditioning equipment and also by general building facilities. In many data centres, IT equipment energy and cooling energy requirements are not always coordinated, so energy consumption is not optimised. Most data centres lack an integrated energy management system that jointly optimises and controls all its energy consuming equipments in order to reduce energy consumption and increase the usage of local renewable energy sources. In this chapter, the authors discuss the challenges of coordinated energy management in data centres and present a novel scalable, integrated energy management system architecture for data centre wide optimisation. A prototype of the system has been implemented, including joint workload and thermal management algorithms. The control algorithms are evaluated in an accurate simulation‐based model of a real data centre. Results show significant energy savings potential, in some cases up to 40%, by integrating workload and thermal management. 2021-02-10T12:58:18Z 2021-06-02T10:09:02Z 2017 chapter ONIX_20210602_10.5772/65989_305 https://library.oapen.org/handle/20.500.12657/49191 https://directory.doabooks.org/handle/20.500.12854/70280 eng open access image/jpeg image/jpeg n/a n/a https://library.oapen.org/bitstream/20.500.12657/49191/1/53179.pdf https://library.oapen.org/bitstream/20.500.12657/49191/1/53179.pdf InTechOpen 10.5772/65989 10.5772/65989 035ecc65-6737-43cf-a13a-6bdf67ce01f4 open access
spellingShingle energy efficient data centres, workload management, thermal management, integrated data centre energy management platform
thema EDItEUR::R Earth Sciences, Geography, Environment, Planning::RN The environment::RNU Sustainability
Kerrison, Steve
Buschhoff, Markus
Nunez-Yanez, Jose
Eder, Kerstin
Chapter Measuring Energy
title Chapter Measuring Energy
title_full Chapter Measuring Energy
title_fullStr Chapter Measuring Energy
title_full_unstemmed Chapter Measuring Energy
title_short Chapter Measuring Energy
title_sort chapter measuring energy
topic energy efficient data centres, workload management, thermal management, integrated data centre energy management platform
thema EDItEUR::R Earth Sciences, Geography, Environment, Planning::RN The environment::RNU Sustainability
topic_facet energy efficient data centres, workload management, thermal management, integrated data centre energy management platform
thema EDItEUR::R Earth Sciences, Geography, Environment, Planning::RN The environment::RNU Sustainability
url ONIX_20210602_10.5772/65989_305
work_keys_str_mv AT kerrisonsteve chaptermeasuringenergy
AT buschhoffmarkus chaptermeasuringenergy
AT nunezyanezjose chaptermeasuringenergy
AT ederkerstin chaptermeasuringenergy